Designed for applications on standard machines with travels up to 520 mm.
With reference marks every 50 mm and detachable cable connector built into the reader head (except the MMK series where the reader head comes standard with a 3-meter attached cable). With very small profile, 5 mm less than the M series they are ideal for tight spaces.
Measuring lengths in millimeters:
40 (*) • 70 (*) • 120 • 140 • 170 • 220 • 270 • 320 • 370 • 420 • 470 • 520
(*) On MMT and MMX models
Measurement | By means of graduated glass scale, with 20 μm etching pitch | ||||||||||
Maximum speed | 60 m/min | ||||||||||
Maximum vibration | 3 g | ||||||||||
Moving thrust | < 5 N | ||||||||||
Operating temperature | 0 ºC … 50 ºC | ||||||||||
Storage temperature | -20 ºC ... 70 ºC | ||||||||||
Weight | 0,58 kg + 0,5 kg/m | ||||||||||
Relative humidity | 20 … 80% | ||||||||||
Protection | IP 53 (standard) IP 64 (DIN 40050) using pressurized air in linear encoders at 0.8 ± 0.2 bar |
||||||||||
Reader head | With detachable cable connector (except MMKT and MMKX) |
MMT | MMKT | MMX | MMKX | MMP | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Accuracy | ± 10 μm | ± 5 μm | ± 10 μm | ± 5 μm | |||||||||||
Resolution | 5 μm | 1 μm | 0,1 μm | ||||||||||||
Reference marks I0 | I0 every 50 mm | ||||||||||||||
Output signals | ![]() |
![]() |
![]() |
||||||||||||
T period of output signals | 20 μm | 4 μm | 20 μm | ||||||||||||
Limit frequency | 50 KHz | 250 KHz | 50 KHz | ||||||||||||
Maximum cable length | 20 m | 50 m | 150 m | ||||||||||||
Supply voltage | 5 V ± 5%,100 mA (without load) | 5 V ± 10%, < 100 mA (without load) |
Example for an incremental encoder : MMT-27 | ||
---|---|---|
MM | T | 27 |
Type of profile: MM: for very limited space
|
Type of signal: • T: 5 μm resolution TTL • X: 1 μm resolution differential TTL • P: 1 Vpp sinusoidal |
Measuring lengths in cm: In the example (27) = 27 cm = 270 mm |