Standard range incremental linear encoders – C Series

Incremental linear encoder - C series

Designed for applications on standard machines with travels up to 3040 mm.

With reference marks every 50 mm or distance-coded and detachable cable connector built into the reader head.

Measuring lengths in millimeters:
220 • 270 • 320 • 370 • 420 • 470 • 520 • 620 • 720 • 770 • 820 • 920 • 1020 • 1140 • 1240 • 1340 • 1440 • 1540 • 1640 • 1740 • 1840 • 1940 • 2040 • 2240 • 2440 • 2640 • 2840 • 3040

General specification:
Measurement By means of graduated glass scale, with 20 μm etching pitch
Maximum speed 60 m/min
Maximum vibration 3 g
Moving thrust < 5 N
Operating temperature 0 ºC … 50 ºC
Storage temperature -20 ºC ... 70 ºC
Weight 1,2 kg + 2,5 kg/m
Relative humidity 20 … 80%
Protection IP 64 (DIN 40050) using pressurized air in linear encoders at 0.8 ± 0.2 bar
Reader head With detachable cable connector
Specific characteristics:
 CT
COT
CX
COX
CP
COP
Accuracy ± 10 μm ± 5 μm
Resolution 5 μm 1 μm Hasta 0,1 μm
Reference marks (I0) CT, CX, CP: every 50 mm
COT, COX, COP: Distance-coded I0
Output signals salida-TTL-diferencial  TTL salida-TTL-diferencial TTL differential onda-senoidal 1 Vpp
T period of output signals 20 μm 4 μm 20 μm
Limit frequency 50 KHz 250 KHz 50 KHz
Maximum cable length 20 m 50 m 150 m
Supply voltage 5 V ± 5%,100 mA (without load) 5 V ± 10%, < 100 mA (without load)

C model:

Order identification:
Example for an incremental encoder : COP – 425
C O P 42 5
Type of profile:
C for wide
spaces
Type of reference mark I0:
• Blank space: Incremental, one
mark every 50 mm
O: Distance-coded marks
Type of signal:
• T: 5 μm Resolution TTL
• X: 1 μm Resolution differential TTL
P: 1 Vpp sinusoidal
Measuring length
in cm:
In the example
(42) = 42 cm = 420 mm
Accuracy of the linear
encoder:
5: ± 5 μm
• Blank space: ± 10 μm